Mode |
Drive # |
Raid Configuration |
|
1 |
2 |
3 |
4 |
JBOD |
RAID 0 |
RAID 1 |
RAID 0+1 |
RAID 1+0 |
RAID 5 |
Capacity w/100GB Drives |
400 GB |
400 GB |
100 GB |
200 GB |
200 GB |
300 GB |
1 |
O |
O |
O |
O |
online |
online |
online |
online |
online |
online |
Single drive failures |
2 |
O |
O |
O |
X |
fail |
fail |
online |
online |
online |
online |
3 |
O |
O |
X |
O |
fail |
fail |
online |
online |
online |
online |
4 |
O |
X |
O |
O |
fail |
fail |
online |
online |
online |
online |
5 |
X |
O |
O |
O |
fail |
fail |
online |
online |
online |
online |
Two drive failures |
6 |
X |
X |
O |
O |
fail |
fail |
online |
online |
fail |
fail |
7 |
X |
O |
X |
O |
fail |
fail |
online |
fail |
online |
fail |
8 |
X |
O |
O |
X |
fail |
fail |
online |
fail |
online |
fail |
9 |
O |
X |
X |
O |
fail |
fail |
online |
fail |
online |
fail |
10 |
O |
X |
O |
X |
fail |
fail |
online |
fail |
online |
fail |
11 |
O |
O |
X |
X |
fail |
fail |
online |
online |
fail |
fail |
Three drive failures |
12 |
X |
X |
X |
O |
fail |
fail |
online |
fail |
fail |
fail |
13 |
X |
X |
O |
X |
fail |
fail |
online |
fail |
fail |
fail |
14 |
X |
O |
X |
X |
fail |
fail |
online |
fail |
fail |
fail |
15 |
O |
X |
X |
X |
fail |
fail |
online |
fail |
fail |
fail |
Four drive failures |
16 |
X |
X |
X |
X |
fail |
fail |
fail |
fail |
fail |
fail |
'X' means the drive failed, while 'O' means the drive is online.
In RAID 0+1, drives in pairs (1,2) and (3,4) are striped,
and then the pairs are mirrored.
In RAID 1+0 or 10, drives in pairs
(1,2) and (3,4) are mirrored, and then the pairs are striped.
|
|